AC line frequency. Bounded tightly, 45 to 65 Hz, because anything outside that band is a scaling error or a sentinel value rather than a grid event. The narrow band is what makes this field a useful canary for a misapplied SunSpec scale factor elsewhere in the same payload.
AC line frequency.
grid_frequency_hzReal tag spellings from Forge's vendor packs, as the device or controller emits them. The reason cross-vendor telemetry is hard is visible in a single column.
| Vendor / pack | Raw tag as the device emits it |
|---|---|
| Fronius | HzF_ACFreqFrequencyAC_Frequency |
| SunSpec 101 | HzF_ACFreqFrequencyAC_Frequency |
| SunSpec 103 | HzF_ACFreqFrequencyAC_Frequency |
| SunSpec 201/202 | HzF_ACFreqFrequencyAC_Frequency |
| SunSpec 203/204 | HzF_ACFreqFrequencyAC_Frequency |
| Schneider | FreqFreq_HzFreq_avgFrequency |
| Victron | Grid/Frequency/Ac/Grid/L1/Frequency |
| SolarEdge (inverter) | I_AC_Frequency |
| SolarEdge (meter) | M_AC_Freq |
| Sungrow | Grid frequency |
These spellings come from the vendor packs in Forge's free sandbox image (ghcr.io/foundrynet/forge-sandbox), which is a different build from prod. To see how prod maps a tag, send it to /v1/normalize: the response names the canonical field, the match_type and the confidence.
The canonical field is not just a name. It is a contract about units, sign convention and plausible range, enforced on the way in and re-checked at read time.
| SI / canonical unit | Hz |
| Accepted input units | Hz |
| Physics bounds | 45.0 to 65.0 Hz |
| Measurement type | instantaneous |
No mapping table to maintain, and no per-vendor branch in your code. The same request shape works for every OEM in the table above.
Read alongside this one.
spindle_speed_rpm spindle_load_pct program_name part_count feed_rate